Description of the DESKLINE ® DL15/DL16 system Each DESKLINE ® DL15/DL16 lifting unit is equipped with a motor and parallel/memory drive is ensured by means of software in the CBD4/CBD5/CBD6 that also takes account of oblique load on the desk. Soft start and stop are also part of this software, which ensures a soft start and stop when adjusting the desk. Application of the DESKLINE ® DL15/DL16 system: Irrespective of the load the duty cycle 10% ~ 6 min./ hour or max. 2 min. at continuous use stated in the data sheets, must NOT be exceeded as this will result in a superheating of the motor, the brake and the spindle nut. Exceeding the duty cycle will result in a dramatic reduction of the life of the system. The DESKLINE ® DL15/DL16 system range contains the following products: • 1 control box CBD4/CBD5/CBD6 • 1 single DL15/DL16 or 2, 3, or 4 parallel • 1 exchangeable mains cable • 1, 2, 3, or 4 motor cables • 1 DP1U/DPF1M (if memory function is required) DP1C/WDPL/DPT/DPF1C/DP1CS (if memory function and display is required) or 1 DPA/DPB/DP1K/DP1V/DPF1K (if only up/down is required) DPF1D (if display is required). Page 10 of 28