The maximum current consumption available for CB7, is 4 Amp in total. It is not possible to run two actuators simultaneously, if the total load on the system requires more than max. 4 Amp. The tolerance of the current cutoff limits are ±10%. With respect to the current cut-off limits, please note that these limits are common cut-off limits. CH2 refers to the CH1 current cut-off limit in the downward direction because of the common cut-off limits. Example: If the current cut-off for CH1 down is 3 Amp, then the current cut-off limits for CH2 up or down, cannot be higher than 3 Amp. Because of the max. current limitation on CB7 (4A ±10% tolerance), it may not be possible to run with full load on the chosen actuator. But only a load which does not exceed the max. current consumption of up to 4A ±10% tolerance. It is not possible to mount the control box on LA29, therefore it is recommended to use LA29 in applications with LA31 dimensions (cB7 mounted on special La31): 153 125 78 163 0 25.9 -0.2 6.1 +0.2 0 62.9 11 17 13 23.5 10.1 Ø 25.9 +0.2 0 S+173 81 27.5 this cover can only be added if the cB7 and the actuator are mounted together. Ø 21.9 +0.2 0 CB07_LA31001C LINAK A/S 153 Ø 10 .1 .2 +0 0